Skip to main content
Administrator Guide
Last Updated: 2023-06-23
Example: Synchronize All Supplier Data Between Workday and Strategic Sourcing

Example: Synchronize All Supplier Data Between Workday and Strategic Sourcing

This example illustrates how to to synchronize all supplier data between Workday and Strategic Sourcing on an ad hoc basis.
Your
Supplier Onboarding
integration system syncs supplier data between Workday and Strategic Sourcing. The integration runs every hour and only syncs suppliers that are new or changed since the last integration run. To ensure data consistency before you start using new functionality, you want to sync all active suppliers in a single ad hoc integration run.
To perform a full sync, you:
  • Suspend your existing integration schedule.
  • Edit the integration to disable change detection and to sync active and approved suppliers only.
  • Run the integration outside business hours to avoid performance issues.
  • Restore the original integration settings and reactivate the hourly integration schedule.
  • Steps: Set Up Supplier Connector for Strategic Sourcing
    Create an integration system named
    Supplier Synchronization
    that only syncs suppliers that changed since the last run. Schedule the integration to run hourly.
  • Security:
    Scheduled Process Management
    domain in the Tenant Non-Configurable functional area, and these domains in the Integration functional area:
    • Integration Build
    • Integration Configure
    • Integration Event
    • Integration Reports
  1. Access the
    Scheduled Future Processes
    report.
    Suspend the existing integration schedule.
    1. From the
      Process
      prompt, select your
      Supplier Synchronization
      integration.
    2. Click
      OK
      .
    3. In the
      Scheduled Process
      column, access the related actions menu of the
      Supplier Synchronization
      process and select
      Schedule Future Process
      Suspend
      .
    4. Click
      OK
      and
      Done
      .
  2. Access the
    All Integration Systems
    report.
    To sync all active supplier data, edit the integration to disable the change detection service and exclude canceled, denied, and inactive suppliers.
    1. From the
      Integration Template
      prompt, select
      Supplier Onboarding (WSS)
      .
    2. Click
      OK
      .
    3. Find your
      Supplier Synchronization
      integration system in the grid.
    4. From the related actions menu of the
      Supplier Synchronization
      integration system, select
      Integration System
      Configure Integration Services
      .
    5. Clear the
      Enabled
      check box for the
      Supplier Onboarding (WSS) Change Detection
      integration service.
    6. Click
      OK
      .
    7. From the related actions menu of the
      Supplier Synchronization
      integration system, select
      Integration System
      Configure Integration Attributes
      .
    8. On the
      approval status
      row, clear
      CANCELED
      and
      DENIED
      from the
      Value
      prompt.
    9. On the
      supplier status
      row, clear
      Inactive
      and
      Hold
      from the
      Value
      prompt.
    10. Click
      OK
      .
  3. From the related actions menu of the
    Supplier Synchronization
    integration system, select
    Integration
    Launch/Schedule
    .
    Schedule the full sync to take place outside business hours.
    1. From the
      Run Frequency
      prompt, select
      Run Once in the Future
      .
    2. Click
      OK
      .
    3. From the
      Start Date
      prompt, select the current date.
    4. From the
      Start Time
      prompt, select
      9:30 PM
      .
    5. Click
      OK
      .
  4. After the integration runs, access the
    All Integration Systems
    report again.
    To restore the original settings, edit the integration to enable the change detection service and include suppliers that you cancel, deny, or inactivate between runs.
    1. From the
      Integration Template
      prompt, select
      Supplier Onboarding (WSS)
      .
    2. Click
      OK
      .
    3. Find your
      Supplier Synchronization
      integration system in the grid.
    4. From the related actions menu of the
      Supplier Synchronization
      integration system, select
      Integration System
      Configure Integration Services
      .
    5. Select the
      Enabled
      check box for the
      Supplier Onboarding (WSS) Change Detection
      integration service.
    6. Click
      OK
      .
    7. From the related actions menu of the
      Supplier Synchronization
      integration system, select
      Integration System
      Configure Integration Attributes
      .
    8. On the
      approval status
      row, select
      CANCELED
      and
      DENIED
      from the
      Value
      prompt.
    9. On the
      supplier status
      row, select
      Inactive
      and
      Hold
      from the
      Value
      prompt.
    10. Click
      OK
      .
  5. Access the
    Scheduled Future Process
    report.
    Reactivate the original integration schedule.
    1. From the
      Process
      prompt, select your
      Supplier Synchronization
      integration.
    2. Click
      OK
      .
    3. In the
      Scheduled Process
      column, access the related actions menu of the
      Supplier Synchronization
      process and select
      Schedule Future Process
      Activate
      .
    4. Click
      OK
      and
      Done
      .